Current location - Health Preservation Learning Network - Slimming men and women - Introduction of negative pressure oxygen respirator
Introduction of negative pressure oxygen respirator
Negative pressure oxygen respirator

Introduction of negative pressure oxygen respirator

Negative pressure oxygen respirator is also called negative pressure isolated compressed oxygen respirator. The respiratory system is isolated from the outside world, and the instrument forms an internal circulation with the human respiratory system. High-pressure gas cylinders provide oxygen, and airbags store breathing and inhaled gases. Stable and reliable performance, widely used in petroleum, chemical industry, metallurgy, coal, mining, laboratory and other industries (departments). Wear it by specially trained personnel when carrying out emergency rescue, accident treatment, rescue or operation in toxic and harmful gas environment (ordinary atmospheric pressure).

Working principle of negative pressure oxygen respirator

The gas exhaled by the wearer from the lungs enters the cleaning tank through the mask, tee joint, exhalation hose and exhalation valve. After the carbon dioxide component in the exhaled gas is absorbed by the absorbent in the cleaning tank, the remaining gas enters the airbag. In addition, the oxygen stored in the oxygen cylinder enters the airbag through the high-pressure conduit and pressure reducer, and the gases merge to form oxygen-containing gas. When the wearer inhales, the oxygen-containing gas enters the human lungs from the airbag through the inhalation valve and the inhalation hose, thus completing a breathing cycle. In this cycle, because the exhalation valve and the inhalation valve are both one-way valves, the airflow always flows in one direction.

Product characteristics of negative pressure oxygen respirator

Wear a mask, the vision is clear, no fog, no frost.

Breathing and sucking hose is a large cross-section hose, which is soft and easy to swing with the head.

The quantitative hole can be adjusted to ensure stable oxygen supply.

The cooler is external, which is convenient for replacing Lan Bing or ice cubes.

The suspenders and belts are made of flame-retardant and antistatic materials, which are soft and wear-resistant, and the back is ergonomically designed.

There is manual drainage device. It has advanced exhaust function.

Technical parameters of negative pressure oxygen respirator

1 rated protection time: > 4h

2. Rated working pressure of oxygen cylinder: 20m pas Shenhua 22

3 Quantitative oxygen supply: 1. 65~ 1。 4L/ min

4 Automatic oxygen supply: ≥80L/min

5 Manual oxygen supply: ≥80L/min

6 Opening pressure of automatic makeup valve:-100~-300Pa

7 Opening pressure of automatic exhaust valve: 100~300Pa

8 pressure: 4 ~ 6 MPa

9 overall dimensions: (excluding hose harness, etc. ) 450*370* 160

10 respirator mass (excluding accessories and tools): ≤ 13KG.