Code for design of fireproof floor stickers?
According to People's Republic of China (PRC)'s Requirements for Setting Fire Safety Signs, the distance between fire safety evacuation exit stickers is 20m. Fire safety exit stickers must use fluorescent materials.

"Emergency Exit" signs should be set on the walls at both sides and corners of the emergency exit evacuation passage, and the upper edge of the signs should not exceed 1m from the ground. You can also set the sign directly on the ground and cover it with a non-combustible transparent and firm protective plate. The spacing between signs should not be greater than 20m, and the distance between the end of the bag-shaped walkway and the signs should not be greater than 10m.

"Requirements for Setting Fire Safety Signs" stipulates the setting principles of fire safety signs and the eye-catching position of the signs. They should be set on movable objects such as door and window frames to avoid contradictions and duplication. The direction should be chosen at the passage, and the observation angle of most observers should be close to 90 degrees.

In order to evacuate people quickly and safely in the event of accidents, a sufficient number of safety exits must be set in the fire protection design of buildings. There should be no less than two safety exits in each building or fire zone. The horizontal distance between two adjacent safety exits in each fire zone or the nearest edge of the evacuation exit in each room should not be less than 5.0m The exits should be evenly distributed and clearly marked. Buildings with fire resistance ratings of Grade I and Grade II.

Tips: When setting fire safety evacuation signs, the contents of the signs should be clear, concise and definite, consistent with what needs to be expressed, and should not contradict each other.

Find it useful. I like it.

word

format

Professional data collation

Code for fire protection design

First, the fire resistance rating of buildings.

1

The fire resistance rating of buildings is divided into four levels, I, II, III and IV.

2

The joint cracks or exposed parts at the joints of metal load-bearing members shall be provided with fire-proof layers.

three

The fire resistance rating, number of floors, length and area of civil buildings, and the length of the first and second major fire zones.

250?

rice. ceiling

Allowable building area

2500?

Square meters.

four

For underground rooms, windowless rooms or above-ground rooms with fixed sashes, and more than

20m?

And there is no natural smoke exhaust.

The walkway may have direct natural ventilation, but the length exceeds

40m?

The evacuation corridor should be equipped with mechanical smoke exhaust facilities.

five

1

) The building height exceeds

32?

Meters, mechanical smoke exhaust facilities should be set up.

2

) corridor exceeds

20?

rice. It is also equipped with natural lighting and natural ventilation facilities. Mechanical smoke exhaust facilities should be set up.

three

) the area exceeds

100?

Square meters, should be equipped with mechanical smoke exhaust facilities.

4)

Ventilation and air conditioning system should be equipped with smoke exhaust system and mechanical smoke exhaust facilities.

Two, the building fire partition, fire spacing and evacuation exits.

six

If there is a horse that communicates with the upper and lower floors in the building.

Gallery,

Escalators and other openings

When,

You should press,

Low connectivity

As a fire zone,

seven

Underground,

Firewalls should be used between fire partitions of semi-underground buildings.

Separated,

The building area of each fire zone should not be too large.

what

500 square meters

eight

When the automatic fire extinguishing system is installed, the maximum allowable building area of each fire zone can be increased.

reach

1000㎡?

. Local settings

When placed, the increased area should be calculated as twice the local area.

Count.

nine

Fire spacing of civil buildings: fire spacing between civil buildings,

six

-

nine

rice

10

There should be no less than two safety exits for public buildings and corridor-style residential buildings.

1 1

Nine floors and below, the construction area does not exceed

500㎡?

Tower houses can be equipped with stairs.

12

Two safety exits must be set for the safety exits or evacuation exits of high-rise buildings.

mouth

13

Safety exits or evacuation exits should be distributed in buildings. in building

Adjoin with

2?

Safety exits or evacuation exits are the most

The horizontal distance between the near edges should not be less than

5.0m

14

Distance from the room door leading directly to the public walkway to the nearest external exit or closed stairwell.

leave

:?

Primary and secondary

level

25?

Rice,

Annular channel

22?

rice. The evacuation distance of a building with automatic sprinkler system can be

raise

25

%

15

The first floor of the stairwell should be provided with a direct external exit. When the number of floors does not exceed four, an external exit can be set.

Placed near the stairwell

15m?

Location.

16

The safety door shall be a bolt-type external door.

17

The partition wall between transformer room and distribution room shall be provided with a firewall. Boiler room and power distribution room should be located outside the first floor.

Part of the wall,

And you should open the door on the outer wall.

The upper part of the first floor external wall hole should be set with a larger width.

what

1.00m?

Fire pick

Cornice or height not less than

1.50m?

Windows.

Third, the outdoor fire hydrant system

18

When the fire lane passes through the door of the building,

Its clear height and width should not be small.

what

4m

; The clear width between battlements cannot be small.

what

3.5 meters

19

The pipeline shaft and cable shaft in the building should be every

different

2

~

3?

Is the fire resistance limit of the floor used?

lower than

0.50h?

noncombustible

When the combustion body is isolated, the shaft wall should adopt a fire resistance rating of not low.

what

1.00h?

Non-combustible body The inspection door on the shaft wall should be protected by Class C.

Fire door.