Current location - Health Preservation Learning Network - Health preserving class - Royalstar high-speed mixer shows what e3 means.
Royalstar high-speed mixer shows what e3 means.
Low pressure protection of compressor.

1, display the query. Com information shows, first determine whether the ambient temperature is too low.

2. Secondly, to judge whether it is a control fault or a system fault, you can first short the LPP plug on the main control board and the zero line N on the main board. If the indoor unit is running normally, it can be determined that there is no problem with the main board or display board of the indoor unit, and the fault occurs in the connecting wire, plug or low-voltage switch of the outdoor unit.

3. Connect the cable and plug of the external machine, set the multimeter on the ohm gear, connect one probe to the LPP protection line unplugged from the motherboard, and connect the other probe to the neutral line N. If the resistance value is 0, the fault is on the low-voltage switch, and vice versa.

4. Judge whether the system leaks fluorine or is blocked by the pressure gauge.