Current location - Health Preservation Learning Network - Healthy weight loss - Products of Weihai Kairui Electric Technology Co., Ltd.
Products of Weihai Kairui Electric Technology Co., Ltd.
At present, Weihai Kerry Electric Technology Co., Ltd. mainly produces HRT3000 electric fire monitoring system and FEPS fire emergency power supply equipment. HRT3000 electrical fire monitoring system is an electrical equipment used to monitor the leakage current of buildings, display the leakage current value, and give early warning and alarm. It is mainly composed of upper computer, monitoring detector, detector and other monitoring system software, CAN bus, bus repeater and high-speed wireless bridge.

HRT3000 series mainly includes the following products:

1, HRT3000-M electrical fire monitoring equipment

Product performance: Windows2000 system working environment;

Display the plane distribution of each monitoring detector, and the interface is friendly and intuitive;

The field CAN bus technology can transmit the operation parameters and control instructions of each detector in real time and accurately.

Overcurrent early warning and alarm; Leakage current early warning and alarm; High risk current cut-off;

Standby power supply system, which can support the system to work for more than 4 hours;

Acousto-optic alarm and remote trip function;

Up to 2048 nodes can be monitored and managed;

Alarm record storage, query and printing functions;

Fault record storage, query and printing functions;

Remote maintenance function.

Equipment parameters: working voltage AC220 10% 50Hz% 50 Hz display screen 17 "color CRT screen alarm mode acousto-optic alarm, alarm sound ≥70dB, storage record ≥ 5 million printer micro-needle or hot standby power supply 4 hours uninterrupted UPS power bus medium ZR-RVS-2X 1.5 twisted pair communication distance ≤/.

Product performance: digital processing technology, real-time monitoring and display of the working status of each distribution line; The field CAN bus technology can transmit the operation parameters and control instructions of each detector in real time and accurately.

Overcurrent early warning and alarm; Residual current early warning alarm; High risk current cut-off;

Standby power supply system, which can support the system to work for more than 4 hours;

Acousto-optic alarm and remote trip function;

Up to 999 nodes can be monitored and managed;

Alarm record storage, query and printing functions;

Fault record storage, query and printing functions.

Equipment parameters: AC 22010% 50hz display, 5.7-inch monochrome LCD display alarm mode, acousto-optic alarm, alarm sound ≥70dB, storage record ≥ 50,000 printers, miniature pin or hot standby power supply, 4-hour uninterrupted UPS bus medium ZR-RVS-2X 1.5 twisted pair communication distance ≤ 0km, ambient temperature -20℃-60℃, relative humidity ≤ 90% RH00mm, equipment size width 400 mm, thickness 150mmX height 600mm, installation method, wall-mounted implementation standard GB 14287. 1-2005 3, HRT3000-A, residual current is

Product performance:

Leakage current value display;

Leakage current early warning and alarm;

Control output (trip circuit breaker) function;

Chinese liquid crystal display

Set equipment parameters manually or remotely on site;

Audible and visual alarm;

Bus communication;

Temperature measurement function (optional temperature detector is required);

It has the function of measuring current (current detector is needed).

Equipment parameters: input voltage AC 220 10% 50hz output trip voltage AC220V passive contact optional alarm mode acousto-optic alarm communication mode CAN bus medium ZR-RVS-2X 1.5 twisted pair communication distance ≤ 10km using environment -20℃-60℃ relative humidity. ≤ 90% RH (40℃ 2℃) ≤4500mm above sea level. Equipment dimension length 180mmX width 100mmX height 76mm. Installation mode: guide rail window type shall comply with the standards GB 14287. 1-2005 4 and HRT 3005.

Product performance:

Leakage current value display;

Leakage current early warning and alarm;

Control output (trip circuit breaker) function;

Chinese LCD;

Set equipment parameters manually or remotely on site;

Audible and visual alarm;

Bus communication;

With temperature measurement function (temperature detector is required);

It has the function of measuring current (current detector is needed).

Equipment parameters: input voltage AC 220 10% 50hz output trip voltage AC220V passive contact optional alarm mode acousto-optic alarm communication mode CAN bus medium ZR-RVS-2X 1.5 twisted pair communication distance ≤ 10km using environment -20℃-60℃ relative humidity. ≤ 90% RH (40℃ 2℃) altitude ≤ 4,500mm Equipment size length 96mmX width 96mmX thickness 100mm Installation mode Panel shall comply with the standard GB 14287. 1-2005.

5.HRT3000-C residual current type electrical fire monitoring detector (not independent)

Product performance:

Single channel leakage current monitoring; Ultra low power consumption; Small size; Convenient installation; Double bus transmission; Equipment operation display.

Equipment parameters: input voltage pulse DC24V communication mode two-bus bus medium ZR-RVS-2X 1.5 twisted pair communication distance ≤ 1500m use environment -20℃-60℃ relative humidity ≤ 90% RH (40℃ 2℃) altitude ≤4500mm equipment size ≤ 72mmX width ≤ The thickness of MX is 58 mm. Installation method: guide rail type electrical fire monitoring detector (independent) according to GB 14287. 1-2005 6 and HRT3000-D.

Product performance:

8-way leakage current monitoring;

8-way temperature monitoring;

Leakage current value display; Leakage current early warning and alarm;

Control output (trip circuit breaker) function;

Chinese LCD;

Set equipment parameters manually or remotely on site;

Field RS232 maintenance interface;

Audible and visual alarm;

Bus communication.

Equipment parameters: input voltage AC 220 10% 50hz output trip voltage AC220V passive contact optional alarm mode acousto-optic alarm communication mode CAN bus medium ZR-RVS-2X 1.5 twisted pair communication distance ≤ 10km using environment -20℃-60℃ relative humidity. ≤ 90% RH (40℃ 2℃) ≤4500mm above sea level. Equipment dimension length 180mmX width 100mmX height 76mm. Installation method: The guide rail window type shall comply with the standards GB 14287. 1-2005 and GB/kloc.

HRT3000-CL control module is specially connected with HRT3000-D electric fire monitoring detector to realize the expansion of control output, which can be extended to 8 control outputs at most to realize the operation of opening the controlled circuit. Parameters/specifications HRT3000-CL. /dchrt3000-cl/achrt3000-cl/nOutput trip voltage DC24V AC220V passive node input voltage 220V AC (175 ~ 245V) 50Hz protection output switch type, contact capacity 250V AC/5A service environment conditions 1.

3. Altitude: no more than 3,000 meters. Place of use: guide rail window type 8, HRT3000-SR leak detector with rain-proof facilities.

A leak detector is a sensor that monitors the detector. Based on Kirchhoff's current law, that is, the vector sum of complex currents flowing into any node in the circuit is equal to zero, the residual current of the power supply line is detected and the residual current signal is input to the monitoring detector.

Equipment parameter specification: sr50sr200sr400sr500sr600sr1600Aperture φ 25 φ 45 φ 65 φ 80 φ100φ150 Current value below 50A 50-200a 200-400a 500-630a 630-65438.

Digital temperature detector is a sensor to monitor the detector. Based on the thermocouple principle of temperature detection element, the temperature of sampling point is detected and the temperature signal is input into the monitoring detector. Installation method of temperature measurement Method of box body temperature measurement ST temperature detector is installed in the box body, and the average temperature rise of the box body is detected by sampling the average temperature of the box body filled with air. Generally, a box needs 1 set of ST. In the cable temperature measurement method, the long-term overcurrent temperature rise of the cable can be detected by pressing the ST temperature detector on the surface of the cable insulation material and sampling the temperature of the insulation material. Generally, each channel needs 1 group ST. 10, HRT3000-CB CAN bus repeater

Product performance:

Integrate two completely electrically isolated CAN channels;

Adopt photoelectric isolation and DC/DC power supply isolation;

With relay function, the communication distance of CAN can be doubled.

The communication baud rate can be set arbitrarily between 5 kbps and 1 Mbps;

High-speed 32-bit microprocessor is adopted to meet the application of large data flow (7000 extended frames per second) without losing data frames.

Equipment parameters: input voltage DC+9V ~ 25V)/ 150mA communication mode CAN bus medium ZR-RVS-2X 1.5 twisted pair communication distance ≤ 10km use environment -20℃ ~+85℃ relative humidity ≤ 90% RH (40℃) MX 25mm high installation mode: rail or simple fixing mode: ISO/DIS1189811,HRT3000-WN CAN bus high-speed wireless bridge.

Product performance:

The software changes the transmission power and mute turn-on level;

Adopt temperature compensation frequency reference source to ensure high and stable transceiver frequency;

Using frequency synthesis technology, the computer can set frequency points flexibly and conveniently;

Built-in modem for direct data transmission;

Point-to-point, point-to-multipoint and flexible networking;

Wireless bridge is divided into transmitting part and receiving part, which need to be used in pairs.

Equipment parameters: frequency range 220 MHz ~ 238 MHz modulation GMSK channel transmission rate 9600/ 19200bps channel spacing 25KHz data interface EIA-232, EIA-485, TTL data interface rate total number of asynchronous data transmission channels 16 power supply voltage DC11v ~ Kloc-0/4V frequency stability 1.5ppm antenna impedance 50Ω antenna installation method The equipment size is145mx and the width is 65. 438+009mmX 4 1mm FEPS-HRT fire emergency power supply equipment is a new type of electrical equipment in fire protection industry introduced by Kerry Electric in 2009, which is mainly used in industry, commerce, national defense, civil and other fields. FEPS-HRT fire emergency power supply equipment is a high-tech environmental protection product developed in cooperation with German experts. It adopts modular inverters produced by internationally renowned manufacturers, the latest fifth-generation IGBT and inverter technology, CPU control, digital circuits and highly integrated electronic components. This product provides the second or third power supply for the first-class load and particularly important load electrical equipment and fire emergency lighting.