Current location - Health Preservation Learning Network - Health preserving class - What details should be paid attention to in the design of beauty and health club?
What details should be paid attention to in the design of beauty and health club?
The design of beauty salons should meet the requirements of Hygienic Code for Beauty Salons.

The site should be located in an area with clean environment, water supply and drainage conditions and power supply, and there should be no dust, harmful gases, radioactive substances and other diffuse pollution sources within 25 meters around the site.

Site setting and layout

(a) beauty salons should be set indoors, and have good ventilation and lighting. The business area of the beauty salon should not be less than 30 square meters. (2) The floor, wall and ceiling of the beauty salon should be paved with non-toxic, tasteless, waterproof and pollution-free materials, and be flat, crack-free and easy to clean. (three) to provide beauty and hairdressing services at the same time, it shall set up a separate beauty and hairdressing business area. (four) beauty salons should be equipped with disinfection facilities for public goods, and beauty salons with a business area of more than 50 square meters should be set up with a special cleaning and disinfection room; (five) beauty salons should set up dressing rooms or lockers for employees, and set up dressing rooms or lockers for customers as needed.

Facility requirements

(a) water supply and drainage facilities beauty salons should have complete water supply and drainage facilities (including hot water supply facilities), drainage facilities have devices to prevent backflow, vector invasion and odor generation, and are equipped with hair filtering devices; The quality of water supply meets the requirements of Hygienic Standard for Drinking Water. (2) The cleaning and disinfection room should be 1. The area should be not less than 3 square meters, with water supply and drainage facilities, good ventilation and lighting, waterproof floor and wall, and easy to clean. The dado is decorated with waterproof materials such as ceramic tiles, and the height is not less than1.5m. It is equipped with operating platform, cleaning, disinfection, cleaning and air disinfection facilities. 2. The cleaning pool should be made of waterproof materials such as stainless steel or ceramics, which is easy to clean and has the capacity to meet the cleaning needs. 3. Disinfection and cleaning facilities should be closed structure, and the volume should meet the requirements of disinfection and cleaning of stored articles and appliances, and be convenient for cleaning. 4. If the ultraviolet lamp is used as the air disinfection device, the ultraviolet wavelength should be 200 ~ 275 nm, and a 30-watt ultraviolet lamp should be installed per 10 square meter according to the room area, and hung in the center of the room, 2 ~ 2.5 meters away from the ground, with the irradiation intensity greater than 70 microwatts. 5. Cleaning, disinfection and cleaning facilities should be clearly marked. (3) Public toilets 1. Public toilets should be equipped with toilets, toilets should be squatting, and sitting toilets should be equipped with disposable sanitary cushions. Toilets should have running water, hand washing equipment and washbasins. 2. The bathroom should be equipped with lighting and mechanical ventilation facilities, and the mechanical ventilation facilities should not be connected with the central air conditioning ventilation system. (4) Storage facilities The storage room or storage cabinet should have sufficient storage space, tightly assembled doors and windows, and good ventilation, lighting, moisture-proof and disease-resistant biological invasion facilities. Articles should be stored in categories, off the ground and off the wall, and clearly marked. (5) Ventilation facilities The ventilation facilities of the beauty salon should be complete and the airflow direction should be reasonable. The installation of central air-conditioning ventilation system shall conform to the requirements of the Measures for the Hygienic Management of Central Air-conditioning Ventilation System in Public Places. If hot water is supplied by coal or liquefied gas, a forced exhaust ventilation device should be used. (VI) Lighting facilities Beauty salons should make full use of natural lighting or well-equipped lighting facilities, and the illumination on the working surface should be no less than 150 lux. (seven) waste storage facilities in beauty salons should be equipped with sealed waste containers. (VIII) Facilities for prevention and control of disease vectors Beauty salons should be equipped with effective dust-proof, rodent-proof and insect-proof facilities, rat-proof nets should be installed at the sewage outlets and vents of the places, and doors and windows should be assembled tightly and seamlessly.

Equipment and tools

(a) beauty salons should be equipped with a sufficient number of towels and beauty tools. The ratio of towels in beauty salons to customer beds should be greater than 10: 1, and the number of public articles and appliances should meet the disinfection turnover requirements. (two) beauty salons should be equipped with workstations, lockers or equipment carts for placing instruments and tools of beauty salons.